Air Cooled TransformerIt is a transformer that uses air as the cooling medium. This term is abbreviated with the ANSI designation AA, indicating open, natural draft ventilated construction.
 
ALAluminum.
 
Alternating Current (ac)A flow of electricity which reaches maximum in one direction, decreases to zero, then reverses itself and reaches maximum in the opposite direction. The cycle is repeated continuously. The number of cycles per second is equal to the frequency.
 
AmalgamA mixture of different elements.
 
AmalgamateThe forming of an amalgam; the union of two materials; an alloy.
 
Ambient Noise LevelThe noise level of the surrounding area, measured in decibels (dB).
 
Ambient TemperatureThe temperature of the atmosphere of surrounding environment. Typically defined by industry standards as 25° C.
 
Ampere (A)Unit of electrical current flow, or rate of flow of electrons.
 
ANSIAmerican National Standards Institute; Electrical standard developed and published as a result of recommended practices and studies made by NEMA and IEEE.
 
ANSI 386American National Standards instituted Standard for high-voltage elbow connectors. Last issue date, 1985. Deadfront arrest interfaces are defined in this standard.
 
ANSI/IEEE C37.4Industry standards for fuses, air switches and accessories.
 
ANSI/IEEE C62-11American Nation Standards Institute Standard for metal oxide surge arresters. Last issue date, 1993.
 
Applied Voltage testA normal power frequency such as 60hz is applied to each winding for one minute. These tests are in accordance with table (3) in ANSI C57-12-01.
 
ArcSparking that results when undesired current flows between two point of differing potential.
 
Arc FollowerAn arc extinguishing extension on the end of an ELS current-limiting fuse, an essential part of the EL Bay-O-Net holder\'s loadbreak rating.
 
Arc Strangler Loadbreaking DeviceThe arc strangler sleeve (red cap) and cocking mechanism on a hinge-style mounted NX or NXII current-limiting fuse that allows all current magnitudes from excitation current through 200 amps to be interrupted positively and safely by opening the fuse with a switchstick.
 
Arc Strangler SwitchbladeSwitchblade with an arc strangler loadbreaking device for hinged style mounting.
 
Arc VoltageThe reaction of a circuit\'s inductance to the rate of current change in the circuit; E = L(di/dt); when a current-limiting fuse operates, there is an associated arc voltage on the system.
 
ArresterA protective device for limiting surge voltages on equipment by diverting surge current and returning the device to its original status. It is capable of repeating these functions as specified.
 
Arrester Voltage RatingRMS value of the maximum 60 Hz voltage to which an arrester should be subjected, even under transient conditions.
 
Arrester, Deadfront TypeAn arrester assembled in a shielded housing providing system insulation and conductive ground shield, intended to be installed in an enclosure for the protection of underground and padmounted distribution equipment and circuits.
 
Arrester, DisconnectA means for disconnecting an arrester after failure in order to prevent a permanent fault on the circuit. It also gives indication of a failed arrester.
 
Arrester, Distribution, Heavy Duty ClassAn arrester normally used to protect overhead distribution systems exposed to severe lightning currents.
 
Arrester, Distribution, Light Duty ClassAn arrester normally installed on and used to protect underground distribution systems where the major portion of the lightning stroke current is discharged by an arrester located at the overhead line/cable junc
 
Arrester, Distribution, Normal Duty ClasAn arrester normally used to protect overhead distribution systems exposed to typical lightning currents.
 
Arrester, Liquid-Immersed TypeAn arrester designed for use immersed in an insulating liquid.
 
Arrester, Riser Pole TypeAn arrester for pole mounting normally used to protect underground distribution cable and equipment.
 
AughtStandard conductor size, i.e. 4 aught designation 4/0.
 
Auto-transformerA transformer in which the primary and secondary have a common winding.
 
AWGAmerican Wire Gauge: A conductor size designation, i.e., size #2 through 4/0. (Refer to aught.)
 